Pressure Loss
 

The total amount of flow of medium -fluid or gas- produced by the pressure washer is used to determine the pressure loss. However, the operating pressure of the unit does not affect the pressure loss. For better understanding of this concept, the table below lists the measurementf a 100 FT long hose. To calculate the pressure loss for other hose lengths, it is calculated proportionally to 100FT length.

For e.g. a 50 FT of hose will have 50% or 1/2 of the amount of loss while a 200 FT of hose will have 200% or double loss of the amount shown in the below table. Besides this, there are a number of factors which may cause pressure loss.

Factors like hose liner ID tolerance, hose inner liner smoothness etc. Also the manner in which a hose is assembled and installed, the type of fittings used and also the temperature of the medium. Also Pressure loss decreases if the hose is positioned uphill. However, the following table’s calculations are not based on taking into consideration the aforesaid factors as these are not very essential.

 

WATER FLOW GPM HOSE INSIDE DIAMETER, INCHES
1/4" 5/16" 3/8" 1/2"
1 54 PSI 20 PSI 7 PSI 2 PSI
2 180 PSI 60 PSI 25 PSI 6 PSI
3 380 PSI 120 PSI 50 PSI 13 PSI
4 - 220 PSI 90 PSI 24 PSI
5 - 320 PSI 130 PSI 34 PSI
6 - - 220 PSI 52 PSI
8 - - 300 PSI 80 PSI
10 - - - 120 PSI